Kings County TAB and Mechanical Acceptance Testing Services
Commercial testing, adjusting, and balancing (TAB) and Title 24 Mechanical Acceptance Testing with Certified TAB Report and NRCA Forms for city inspections.
- Air Balancing
- Hydronic Balancing
- Mechanical Acceptance Testing
NCI Certified
TAB Professional
RSES Certified
Title 24 NRCA Experts
Serving All of
Countywide Service
Certified Reports
Same-Day Service
Our Kings County Services
Kings County projects can receive commercial TAB and Mechanical Acceptance Testing.
Air Balancing
Commercial air balancing is available for HVAC systems.
Hydronic Balancing
Hydronic balancing is available for chilled-water and hot-water systems.
Mechanical Acceptance Testing
Title 24 Mechanical Acceptance Testing and NRCA Forms for Kings County Code Compliance.
Commercial Air Balancing Services in Kings County
HVAC System Air Balancing
Commercial HVAC air balancing is available for project testing and closeout.
Restaurant Hood Certification
Restaurant hood airflow testing and certification are available when required.
Fume Hood Testing
Commercial fume hood airflow testing is available for the confirmed scope.
Air Balance Reports
Kings County TAB reports document tested systems, measured results, adjustments, and final values.
Hydronic System Balancing
Hydronic TAB Reports
Kings County hydronic TAB reports record measured flow, final settings, and project observations.
Title 24 Mechanical Acceptance Testing in Kings County
Mechanical Acceptance Testing in Kings County follows the applicable procedures identified in the project compliance documents.
Testing and Closeout Support
Required procedures depend on the installed equipment, compliance documents, code cycle, confirmed scope, and current technician and employer qualifications.
- NRCA-MCH-02-A Outdoor Air Acceptance
- NRCA-MCH-03-A HVAC and Heat Pumps – Constant Volume Single Zone HVAC
- NRCA-MCH-04-A Duct Leakage
- NRCA-MCH-05-A Economizer, Dedicated Outdoor Air System (DOAS), Heat Recovery Ventilator (HRV), and Energy Recovery Ventilator (ERV)
- NRCA-MCH-06-A Demand Control Ventilation
- NRCA-MCH-07-A Supply Fan Variable Flow Controls
- NRCA-MCH-08-A Valve Leakage Test
- NRCA-MCH-09-A Water Temperature Reset
- NRCA-MCH-10-A Hydronic System Variable Flow Controls
- NRCA-MCH-11-A Automatic Demand Shed Control
- NRCA-MCH-12-A Fault Detection and Diagnostics (FDD) – Packaged Units
- NRCA-MCH-13-A Air Handling Unit (AHU) and Zone Terminal Fault Detection and Diagnostics (FDD)
- NRCA-MCH-14-A Distributed Energy Storage Direct Expansion Air Conditioning (DX AC) Systems
- NRCA-MCH-15-A Thermal Energy Storage
- NRCA-MCH-16-A Supply Air Temperature Reset Controls
- NRCA-MCH-17-A Condenser Water Temperature Reset Controls
- NRCA-MCH-18-A Energy Management Control System (EMCS) Acceptance
- NRCA-MCH-19-A Occupied Standby
Frequently Asked Questions
What Is the Difference Between TAB and Mechanical Acceptance Testing?
Kings County TAB measures and adjusts commercial HVAC systems to documented project values. Mechanical Acceptance Testing completes applicable California Energy Code procedures for listed equipment and controls. The confirmed scope determines whether a project needs either service or both.
Why May TAB Be Required on a Project?
TAB may be required when approved plans, specifications, permit documents, or the reviewing authority call for measured HVAC system verification.
Cities We Provide Air Balancing In Throughout Kings County
Vortex provides commercial air balancing throughout Kings County, including every incorporated city listed below:
- Avenal
- Corcoran
- Hanford
- Lemoore
Is Mechanical Acceptance Testing Included with TAB?
Mechanical Acceptance Testing is separate from TAB and is included only when required by the project documents and confirmed scope.
Who Can Perform Mechanical Acceptance Testing?
Kings County Mechanical Acceptance Testing must be completed under the technician and employer qualifications required for the applicable Energy Code procedures. Vortex performs only work within its current qualifications and confirmed scope.
Who Can Perform TAB?
TAB qualifications for Kings County projects should match the approved plans, specifications, engineer requirements, and enforcing agency direction. Vortex uses NCI-certified TAB technicians and calibrated instruments.
Can Vortex Coordinate TAB and MAT?
Yes. Vortex can coordinate TAB and Mechanical Acceptance Testing when both services are included in the confirmed project scope and the required procedures fall within current qualifications.